SF6 Gas Density Gauge  



 

             
Electrical Data
 
electrical contacts
1/2/3 of low or high pressure
permanent current
0,6A
making and breaking current
0,7A
switching capacity
10W 18VA, 250 V max.
nominal voltage
250 V
hysterisis
0,3 ....0,5% of full scale value
accuracy of contacts
+/- 2% of full scale value in the range of temperature wih reference
to the nominal isochore curve
molecular leakage rate
<1x10 -5 mlbar/sec
 

             
Measurements
Ø100mm
d in mm
117
d1 in mm
103
H in mm
155
h in mm
115
weight in kg
0,8